         Problem Statement: Overlays for Network Virtualization
             draft-narten-nvo3-overlay-problem-statement-01

Abstract

   This document describes issues associated with providing multi-
   tenancy in large data center networks and an overlay-based network
   virtualization approach to addressing them.  A key multi-tenancy
   requirement is traffic isolation, so that a tenant's traffic is not
   visible to any other tenant.  This isolation can be achieved by
   assigning one or more virtual networks to each tenant such that
   traffic within a virtual network is isolated from traffic in other
   virtual networks.  The primary functionality required is provisioning
   virtual networks, associating a virtual machine's NIC with the
   appropriate virtual network, and maintaining that association as the
   virtual machine is activated, migrated and/or deactivated.  Use of an
   overlay-based approach enables scalable deployment on large network
   infrastructures.

Status of this Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on May 3, 2012.



Narten, et al.             Expires May 3, 2012                  [Page 1]

Internet-Draft     Overlays for Network Virtualization      October 2011


Copyright Notice

   Copyright (c) 2011 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.





































Narten, et al.             Expires May 3, 2012                  [Page 2]

Internet-Draft     Overlays for Network Virtualization      October 2011


Table of Contents

   1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . .  4
   2.  Problem Details  . . . . . . . . . . . . . . . . . . . . . . .  5
     2.1.  Multi-tenant Environment Scale . . . . . . . . . . . . . .  5
     2.2.  Virtual Machine Mobility Requirements  . . . . . . . . . .  5
     2.3.  Span of Virtual Networks . . . . . . . . . . . . . . . . .  5
     2.4.  Inadequate Forwarding Table Sizes in Switches  . . . . . .  6
     2.5.  Decoupling Logical and Physical Configuration  . . . . . .  6
     2.6.  Support Communication Between VMs and Non-virtualized
           Devices  . . . . . . . . . . . . . . . . . . . . . . . . .  6
     2.7.  Overlay Design Characteristics . . . . . . . . . . . . . .  6
   3.  Defining Virtual Networks and Tenants  . . . . . . . . . . . .  7
     3.1.  Limitations of Existing Virtual Network Models . . . . . .  8
     3.2.  Virtual Network Instance . . . . . . . . . . . . . . . . .  8
     3.3.  Tenant . . . . . . . . . . . . . . . . . . . . . . . . . .  9
   4.  Network Overlays . . . . . . . . . . . . . . . . . . . . . . .  9
     4.1.  Benefits of an Overlay Approach  . . . . . . . . . . . . . 10
     4.2.  Standardization Issues for Overlay Networks  . . . . . . . 10
       4.2.1.  Overlay Header Format  . . . . . . . . . . . . . . . . 10
       4.2.2.  Fragmentation  . . . . . . . . . . . . . . . . . . . . 11
       4.2.3.  Checksums and FCS  . . . . . . . . . . . . . . . . . . 11
       4.2.4.  Middlebox Traversal  . . . . . . . . . . . . . . . . . 12
       4.2.5.  OAM  . . . . . . . . . . . . . . . . . . . . . . . . . 12
   5.  Control Plane  . . . . . . . . . . . . . . . . . . . . . . . . 12
     5.1.  Populating the Forwarding Table of a Virtual Network
           Instance . . . . . . . . . . . . . . . . . . . . . . . . . 12
     5.2.  Handling Multi-destination Frames  . . . . . . . . . . . . 13
     5.3.  Associating a VNID With An Endpoint  . . . . . . . . . . . 13
     5.4.  Disassociating a VNID on Termination or Move . . . . . . . 13
   6.  Related Work . . . . . . . . . . . . . . . . . . . . . . . . . 13
     6.1.  ARMD . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
     6.2.  TRILL  . . . . . . . . . . . . . . . . . . . . . . . . . . 14
     6.3.  L2VPNs . . . . . . . . . . . . . . . . . . . . . . . . . . 14
     6.4.  Proxy Mobile IP  . . . . . . . . . . . . . . . . . . . . . 14
     6.5.  LISP . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
     6.6.  Individual Submissions . . . . . . . . . . . . . . . . . . 15
   7.  Further Work . . . . . . . . . . . . . . . . . . . . . . . . . 15
   8.  Summary  . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
   9.  Acknowledgments  . . . . . . . . . . . . . . . . . . . . . . . 15
   10. IANA Considerations  . . . . . . . . . . . . . . . . . . . . . 15
   11. Security Considerations  . . . . . . . . . . . . . . . . . . . 15
   12. Informative References . . . . . . . . . . . . . . . . . . . . 16
   Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 17







Narten, et al.             Expires May 3, 2012                  [Page 3]

Internet-Draft     Overlays for Network Virtualization      October 2011


1.  Introduction

   Server virtualization is increasingly becoming the norm in data
   centers.  With server virtualization, each physical server supports
   multiple virtual machines (VMs), each running its own operating
   system, middleware and applications.  Virtualization is a key enabler
   of workload agility, i.e., allowing any server to host any
   application and providing the flexibility of adding, shrinking, or
   moving services within the physical infrastructure.  Server
   virtualization provides numerous benefits, including higher
   utilization, increased data security, reduced user downtime, reduced
   power usage, etc.

   Large scale multi-tenant data centers are taking advantage of the
   benefits of server virtualization to provide a new kind of hosting, a
   virtual hosted data center.  Multi-tenant data centers are ones in
   which each tenant could belong to a different company (in the case of
   a public provider) or a different department (in the case of a
   internal company data center).  Each tenant has the expectation of a
   level of security and privacy separating their resources from those
   of other tenants.  Each virtual data center looks similar to its
   physical counterpart, consisting of end stations connected by a
   network, complete with services such as load balancers and firewalls.
   The network within each virtual data center can be a pure routed
   network, a pure bridged network or a combination of bridged and
   routed network.  The key requirement is that each such virtual
   network is isolated from the others, whether the networks belong to
   the same tenant or different tenants.

   This document outlines the problems encountered in scaling the number
   of isolated networks in a data center, as well as the problems of
   managing the creation/deletion, membership and span of these networks
   and makes the case that an overlay based approach, where individual
   networks are implemented within individual virtual networks that are
   dynamically controlled by a standardized control plane provides a
   number of advantages over current approaches.  The purpose of this
   document is to identify the set of problems that any solution has to
   address in building multi-tenant data centers.  With this approach,
   the goal is to allow the construction of standardized, interoperable
   implementations to allow the construction of multi-tenant data
   centers.

   Section 2 describes the problem space details.  Section 3 defines
   virtual networks.  Section 4 provides a general discussion of
   overlays and standardization issues.  Section 5 discusses the control
   plane issues that require addressing for virtual networks.  Section 6
   and 7 discuss related work and further work.




Narten, et al.             Expires May 3, 2012                  [Page 4]

Internet-Draft     Overlays for Network Virtualization      October 2011


2.  Problem Details

   The following subsections describe aspects of multi-tenant networking
   that pose problems for large scale network infrastructure.  Different
   problem aspects may arise based on the network architecture and
   scale.

2.1.  Multi-tenant Environment Scale

   Cloud computing involves on-demand elastic provisioning of resources
   for multi-tenant environments.  A common example of cloud computing
   is the public cloud, where a cloud service provider offers these
   elastic services to multiple customers over the same infrastructure.
   This elastic on-demand nature in conjunction with trusted hypervisors
   to control network access by VMs calls for resilient distributed
   network control mechanisms.

2.2.  Virtual Machine Mobility Requirements

   A key benefit of server virtualization is virtual machine (VM)
   mobility.  A VM can be migrated from one server to another, live i.e.
   as it continues to run and without shutting down the VM and
   restarting it at a new location.  A key requirement for live
   migration is that a VM retain its IP address(es) and MAC address(es)
   in its new location (to avoid tearing down existing communication).
   Today, servers are assigned IP addresses based on their physical
   location, typically based on the ToR (Top of Rack) switch for the
   server rack or the VLAN configured to the server.  This works well
   for physical servers, which cannot move, but it restricts the
   placement and movement of the more mobile VMs within the data center
   (DC).  Any solution for a scalable multi-tenant DC must allow a VM to
   be placed (or moved to) anywhere within the data center, without
   being constrained by the subnet boundary concerns of the host
   servers.

2.3.  Span of Virtual Networks

   Another use case is cross pod expansion.  A pod typically consists of
   one or more racks of servers with its associated network and storage
   connectivity.  Tenants may start off on a pod and, due to expansion,
   require servers/VMs on other pods, especially the case when tenants
   on the other pods are not fully utilizing all their resources.  This
   use case requires that virtual networks span multiple pods in order
   to provide connectivity to all of the tenant's servers/VMs.







Narten, et al.             Expires May 3, 2012                  [Page 5]

Internet-Draft     Overlays for Network Virtualization      October 2011


2.4.  Inadequate Forwarding Table Sizes in Switches

   Today's virtualized environments place additional demands on the
   forwarding tables of switches.  Instead of just one link-layer
   address per server, the switching infrastructure has to learn
   addresses of the individual VMs (which could range in the 100s per
   server).  This is a requirement since traffic from/to the VMs to the
   rest of the physical network will traverse the physical network
   infrastructure.  This places a much larger demand on the switches'
   forwarding table capacity compared to non-virtualized environments,
   causing more traffic to be flooded or dropped when the addresses in
   use exceeds the forwarding table capacity.

2.5.  Decoupling Logical and Physical Configuration

   Data center operators must be able to achieve high utilization of
   server and network capacity.  For efficient and flexible allocation,
   operators should be able to spread a virtual network instance across
   servers in any rack in the data center.  It should also be possible
   to migrate compute workloads to any server anywhere in the network
   while retaining the workload's addresses.  This can be achieved today
   by stretching VLANs (e.g., by using TRILL or OTV).

   However, in order to limit the broadcast domain of each VLAN, multi-
   destination frames within a VLAN should optimally flow only to those
   devices that have that VLAN configured.  When workloads migrate, the
   physical network (e.g., access lists) may need to be reconfigured
   which is typically time consuming and error prone.

2.6.  Support Communication Between VMs and Non-virtualized Devices

   Within data centers, not all communication will be between VMs.
   Network operators will continue to use non-virtualized servers for
   various reasons, traditional routers to provide L2VPN and L3VPN
   services, traditional load balancers, firewalls, intrusion detection
   engines and so on.  Any virtual network solution should be capable of
   working with these existing systems.

2.7.  Overlay Design Characteristics

   There are existing layer 2 overlay protocols in existence, but they
   were not necessarily designed to solve the problem in the environment
   of a highly virtualized data center.  Below are some of the
   characteristics of environments that must be taken into account by
   the overlay technology:






Narten, et al.             Expires May 3, 2012                  [Page 6]

Internet-Draft     Overlays for Network Virtualization      October 2011


   1.  Highly distributed systems.  The overlay should work in an
       environment where there could be many thousands of access
       switches (e.g. residing within the hypervisors) and many more end
       systems (e.g.  VMs) connected to them.  This leads to a
       distributed mapping system that puts a low overhead on the
       overlay tunnel endpoints.

   2.  Many highly distributed virtual networks with sparse
       connectivity.  Each virtual network could be highly dispersed
       inside the data center.  Also, along with expectation of many
       virtual networks, the number of end systems connected to any one
       virtual network is expected to be relatively low; Therefore, the
       percentage of access switches participating in any given virtual
       network would also be expected to be low.  For this reason,
       efficient pruning of multi-destination traffic should be taken
       into consideration.

   3.  Highly dynamic end systems.  End systems connected to virtual
       networks can be very dynamic, both in terms of creation/deletion/
       power-on/off and in terms of mobility across the access switches.

   4.  Work with existing, widely deployed network Ethernet switches and
       IP routers without requiring wholesale replacement.  The first
       hop switch that adds and removes the overlay header will require
       new equipment and/or new software.

   5.  Network infrastructure administered by a single administrative
       domain.  This is consistent with operation within a data center,
       and not across the Internet.


3.  Defining Virtual Networks and Tenants

   Virtual Networks are used to isolate a tenant's traffic from other
   tenants (or even traffic within the same tenant that requires
   isolation).  There are two main characteristics of virtual networks:

   1.  Providing network address space that is isolated from other
       virtual networks.  The same network addresses may be used in
       different virtual networks on the same underlying network
       infrastructure.

   2.  Limiting the scope of frames to not exit a virtual network except
       through controlled exit points or "gateways".







Narten, et al.             Expires May 3, 2012                  [Page 7]

Internet-Draft     Overlays for Network Virtualization      October 2011


3.1.  Limitations of Existing Virtual Network Models

   Virtual networks are not new to networking.  VLANs are a well known
   construct in the networking industry.  VLAN is a bridging construct
   which provides the semantics of virtual networks mentioned above: a
   MAC address is unique within a VLAN, but not necessarily across VLANs
   and broadcast traffic is limited to the VLAN it originates from.  In
   the case of IP networks, routers have the concept of a Virtual
   Routing and Forwarding (VRF).  The same router can run multiple
   instances of routing protocols, each with their own forwarding table.
   Each instance is referred to as a VRF, which is a mechanism that
   provides address isolation.  Since broadcasts are never forwarded
   across IP subnets, limiting broadcasts are not applicable to VRFs.
   In the case of both VLAN and VRF, the forwarding table is looked up
   using the tuple {VLAN, MAC address} or {VRF, IP address}.

   But there are two problems with these constructs.  VLANs are a pure
   bridging construct while VRF is a pure routing construct.  VLANs are
   carried along with a frame to allow each forwarding point to know
   what VLAN the frame belongs to.  VLAN today is defined as a 12 bit
   number, limiting the total number of VLANs to 4096 (though typically,
   this number is 4094 since 0 and 4095 are reserved).  Due to the large
   number of tenants that a cloud provider might service, the 4094 VLAN
   limit is often inadequate.  In addition, there is often a need for
   multiple VLANs per tenant, which exacerbates the issue.

   There is no VRF indicator carried in frames.  The VRF is derived at
   each hop using a combination of incoming interface and some
   information in the frame.  Furthermore, the VRF model has typically
   assumed that a separate control plane governs the population of the
   forwarding table within that VRF.  Thus, a traditional VRF model
   assumes multiple, independent control planes and has no specific tag
   within a frame to identify the VRF of the frame.

3.2.  Virtual Network Instance

   To overcome the limitations of a traditional VLAN or VRF model, we
   define a new mechanism for virtual networks called a virtual network
   instance.  Each virtual network is assigned a virtual network
   instance ID, shortened to VNID for convenience.  A virtual network
   instance provides the semantics of a virtual network: address
   disambiguation and multi-destination frame scoping.  A virtual
   network can be either routed or bridged.  So, a VNID can be used for
   both bridged networks and routed networks and so is unlike a VLAN or
   a VRF.  To build large multi-tenant data centers, a larger number
   space than the 12b VLAN is required. 24 bits is the most common value
   identified by multiple solutions that attempt to address this problem
   space (or similar problem spaces).  To simplify the building and



Narten, et al.             Expires May 3, 2012                  [Page 8]

Internet-Draft     Overlays for Network Virtualization      October 2011


   administration of these large data centers, we require that the VNID
   be carried with each frame (similar to a VLAN, but unlike a VRF).
   Finally, because of the nature of a virtual data center and to allow
   scaling virtual networks to massive scales, we don't require a
   separate control plane to run for each virtual network.  We'll
   identify other possible mechanisms to populate the forwarding tables
   for virtual networks in section 5.1.

3.3.  Tenant

   Tenant is the administrative entity that that is responsible for and
   manages a specific virtual network and its associated services
   (whether virtual or physical).  In a cloud environment, a tenant
   would correspond to the customer that has defined and is using a
   particular virtual network.  However, there is a one-to-many mapping
   between tenants and virtual network instances.  A single tenant may
   operate multiple individual virtual networks, each associated with a
   different service.


4.  Network Overlays

   To address the problems of decoupling physical and logical
   configuration and allowing VM mobility without exploding the
   forwarding table sizes in the switches and routers, a network overlay
   model can be used.

   The idea behind an overlay is quite straightforward.  The original
   frame is encapsulated by the first hop network device.  The
   encapsulation identifies the destination as the device that will
   perform the decapsulation before delivering the frame to the
   endpoint.  The rest of the network forwards the frame based on the
   encapsulation header and can be oblivious to the payload that is
   carried inside.  To avoid belaboring the point each time, the first
   hop network device can be a traditional switch or router or the
   virtual switch residing inside a hypervisor.  Furthermore, the
   endpoint can be a VM or it can be a physical server.  Some examples
   of network overlays are tunnels such as IP GRE [RFC2784],
   LISP[I-D.ietf-lisp] or TRILL [RFC6325].

   With an overlay, the VNID can be carried within the overlay header so
   that every frame has its VNID explicitly identified in the frame.
   Since both routed and bridged semantics can be supported by a virtual
   data center, the original frame carried within the overlay header can
   be an Ethernet frame complete with MAC addresses or just the IP
   packet.





Narten, et al.             Expires May 3, 2012                  [Page 9]

Internet-Draft     Overlays for Network Virtualization      October 2011


4.1.  Benefits of an Overlay Approach

   The use of a large (e.g., 24-bit) VNID would allow 16 million
   distinct virtual networks within a single data center, eliminating
   current VLAN size limitations.  This VNID needs to be carried in the
   data plane along with the packet.  Adding an overlay header provides
   a place to carry this VNID.

   A key aspect of overlays is the decoupling of the "virtual" MAC and
   IP addresses used by VMs from the physical network infrastructure and
   the infrastructure IP addresses used by the data center.  If a VM
   changes location, the switches at the edge of the overlay simply
   update their mapping tables to reflect the new location of the VM
   within the data center's infrastructure space.  Because an overlay
   network is used, a VM can now be located anywhere in the data center
   that the overlay reaches without regards to traditional constraints
   implied by L2 properties such as VLAN numbering, or the span of an L2
   broadcast domain scoped to a single pod or access switch.

   Multi-tenancy is supported by isolating the traffic of one virtual
   network instance from traffic of another.  Traffic from one virtual
   network instance cannot be delivered to another instance without
   (conceptually) exiting the instance and entering the other instance
   via an entity that has connectivity to both virtual network
   instances.  Without the existence of this entity, tenant traffic
   remains isolated within each individual virtual network instance.
   External communications (from a VM within a virtual network instance
   to a machine outside of any virtual network instance, e.g. on the
   Internet) is handled by having an ingress switch forward traffic to
   an external router, where an egress switch decapsulates a tunneled
   packet and delivers it to the router for normal processing.  This
   router is external to the overlay, and behaves much like existing
   external facing routers in data centers today.

   Overlays are designed to allow a set of VMs to be placed within a
   single virtual network instance, whether that virtual network
   provides the bridged network or a routed network.

4.2.  Standardization Issues for Overlay Networks

4.2.1.  Overlay Header Format

   Different overlay header formats are possible as are different
   possible encodings of the VNID.  Existing overlay headers maybe
   extended or new ones defined.  This document does not address the
   exact header format or VNID encoding except to state that any
   solution MUST:




Narten, et al.             Expires May 3, 2012                 [Page 10]

Internet-Draft     Overlays for Network Virtualization      October 2011


   1.  Carry the VNID in each frame

   2.  Allow the payload to be either a complete Ethernet frame or only
       an IP packet

4.2.2.  Fragmentation

   Whenever tunneling is used, one faces the potential problem that the
   packet plus the encapsulation overhead will exceed the MTU of the
   path to the egress router.  If the outer encapsulation is IP,
   fragmentation could be left to the IP layer, or it could be done at
   the overlay level in a more optimized fashion that is independent of
   the overlay encapsulation header, or it could be left out altogether,
   if it is believed that data center networks can be engineered to
   prevent MTU issues from arising.

   Related to fragmentation is the question of how best to handle Path
   MTU issues, should they occur.  Ideally, the original source of any
   packet (i.e, the sending VM) would be notified of the optimal MTU to
   use.  Path MTU problems occurring within an overlay network would
   result in ICMP MTU exceeded messages being sent back to the egress
   tunnel switch at the entry point of the overlay.  If the switch is
   embedded within a hypervisor, the hypervisor could notify the VM of a
   more appropriate MTU to use.  It may be appropriate to specify a set
   of best practices for implementers related to the handling of Path
   MTU issues.

4.2.3.  Checksums and FCS

   When tunneling packets, both the inner and outer headers could have
   their own checksum, duplicating effort and impacting performance.
   Therefore, we strongly recommend that any solution carry only one set
   of checksum or frame FCS.

   When the inner packet is TCP or UDP, they already include their own
   checksum, and adding a second outer checksum (using the same 1's
   complement algorithm) provides little value.  Similarly, if the inner
   packet is an Ethernet frame, the frame FCS protects the original
   frame and a new frame FCS over both the original frame and the
   overlay header protects the new encapsulated frame.

   In IPv4, UDP checksums can be disabled on a per-packet basis simply
   by setting the checksum field to zero.  IPv6, however, specifies that
   UDP checksums must always be included.  But even for IPv6, the LISP
   protocol[I-D.ietf-lisp] already allows a zero checksum field.  The
   6man working group is also currently considering relaxing the IPv6
   UDP checksum requirement [I-D.ietf-6man-udpzero].




Narten, et al.             Expires May 3, 2012                 [Page 11]

Internet-Draft     Overlays for Network Virtualization      October 2011


   For Ethernet frames, L2 overlays such as TRILL already mandate only a
   single frame FCS.

4.2.4.  Middlebox Traversal

   One issue to consider is to whether the overlay will need to run over
   networks that include middleboxes such as NAT.  Middleboxes may have
   difficulty properly supporting multicast or other aspects of an
   overlay header.  Inside a data center, it may well be the case that
   middlebox traversal is a non-issue.  But if overlays are extended
   across the broader Internet, the presence of middleboxes may be of
   concern.

4.2.5.  OAM

   Successful deployment of an overlay approach will likely require
   appropriate Operations, Administration and Maintenance (OAM)
   facilities.


5.  Control Plane

   The control plane needs to address the following pieces, at least:

   1.  A mechanism to populate the forwarding table of a virtual network
       instance.

   2.  A mechanism to handle multi-destination frames within a virtual
       network instance.

   3.  A mechanism to allow an endpoint to inform the access switch
       which virtual network instance it wishes to join on a virtual
       network interface.

   4.  A mechanism to allow an endpoint to inform the access switch
       about its leaving the network so that the access switch can clean
       up state.

5.1.  Populating the Forwarding Table of a Virtual Network Instance

   When an access switch has to forward a frame from one endpoint to
   another, across the network, it has to consult some form of a
   forwarding table.  When we use network overlays, the problem boils
   down to deriving the mapping between the inner and outer addresses
   i.e. deriving the destination address in the overlay header based on
   the destination address sent by the endpoint.  Two well known
   mechanisms for populating the forwarding table (or deriving the
   mapping table) of a switch are (i) via a routing control protocol and



Narten, et al.             Expires May 3, 2012                 [Page 12]

Internet-Draft     Overlays for Network Virtualization      October 2011


   (ii) learning from the data plane as Ethernet bridges do.  Another
   mechanism is through a centralized mapping database.  Any solution
   must avoid problems associated with scaling a virtual network
   instance across a large data center.

5.2.  Handling Multi-destination Frames

   Another aspect of address mapping concerns the handling of multi-
   destination frames, i.e. broadcast and multicast frames, or the
   delivery of unicast packets when no mapping exists.  Associating a
   infrastructure multicast address is one possible way of connecting
   together all the machines belonging to the same VNID.  However,
   existing multicast implementations do not scale to efficiently handle
   hundreds of thousands of multicast groups, as would be required if
   one multicast group were assigned to each VNID.

5.3.  Associating a VNID With An Endpoint

   When an endpoint, such as VM or physical server, connects to the
   infrastructure, we must define a mechanism to allow the endpoint to
   identify to the access switch the network instance that it wishes to
   join.  Typically, it is a virtual NIC (the one connected to the VM)
   coming up that triggers this association.  The access switch can then
   determine the VNID to be associated with this virtual NIC.  A
   standard protocol that all types of overlay encapsulation points can
   use to identify the VNID associated with an endpoint will be
   beneficial for supporting multi-vendor implementations.  This
   protocol could also be used to distribute any per virtual network
   information (e.g. a multicast group address).  This signaling can
   provide the stimulus to trigger the overlay termination points to
   perform any actions needed within the infrastructure network (e.g.
   use IGMP to join a multicast group).

5.4.  Disassociating a VNID on Termination or Move

   To enable cleaning up state in the access switch, we must define a
   mechanism to allow an endpoint to signal its disconnection from the
   network.


6.  Related Work

6.1.  ARMD

   ARMD is chartered to look at data center scaling issues with a focus
   on address resolution.  ARMD is currently chartered to develop a
   problem statement and is not currently developing solutions.  While
   an overlay-based approach may address some of the "pain points" that



Narten, et al.             Expires May 3, 2012                 [Page 13]

Internet-Draft     Overlays for Network Virtualization      October 2011


   have been raised in ARMD (e.g., better support for multi-tenancy), an
   overlay approach may also push some of the L2 scaling concerns (e.g.,
   excessive flooding) to the IP level (flooding via IP multicast).
   Analysis will be needed to understand the scaling trade offs of an
   overlay based approach compared with existing approaches.  On the
   other hand, existing IP-based approaches such as proxy ARP may help
   mitigate some concerns.

6.2.  TRILL

   TRILL is an L2 based approach aimed at improving deficiencies and
   limitations with current Ethernet networks.  Approaches to extend
   TRILL to support more than 4094 VLANs are currently under
   investigation [I-D.eastlake-trill-rbridge-fine-labeling]

6.3.  L2VPNs

   The IETF has specified a number of approaches for connecting L2
   domains together as part of the L2VPN Working Group.  That group,
   however has historically been focused on Provider-provisioned L2
   VPNs, where the service provider participates in management and
   provisioning of the VPN.  In addition, much of the target environment
   for such deployments involves carrying L2 traffic over WANs.  Overlay
   approaches are intended be used within data centers where the overlay
   network is managed by the data center operator, rather than by an
   outside party.  While overlays can run across the Internet as well,
   they will extend well into the data center itself (e.g., up to and
   including hypervisors) and include large numbers of machines within
   the data center itself.

   Other L2VPN approaches, such as L2TP [RFC2661] require significant
   tunnel state at the encapsulating and decapsulating end points.
   Overlays require less tunnel state than other approaches, which is
   important to allow overlays to scale to hundreds of thousands of end
   points.  It is assumed that smaller switches (i.e., virtual switches
   in hypervisors or the physical switches to which VMs connect) will be
   part of the overlay network and be responsible for encapsulating and
   decapsulating packets.

6.4.  Proxy Mobile IP

   Proxy Mobile IP [RFC5213] [RFC5844] makes use of the GRE Key Field
   [RFC5845] [RFC6245], but not in a way that supports multi-tenancy.

6.5.  LISP

   LISP[I-D.ietf-lisp] essentially provides an IP over IP overlay where
   the internal addresses are end station Identifiers and the outer IP



Narten, et al.             Expires May 3, 2012                 [Page 14]

Internet-Draft     Overlays for Network Virtualization      October 2011


   addresses represent the location of the end station within the core
   IP network topology.  The LISP overlay header uses a 24 bit Instance
   ID used to support overlapping inner IP addresses.

6.6.  Individual Submissions

   Many individual submissions also look to addressing some or all of
   the issues addressed in this draft.  Examples of such drafts are
   VXLAN [I-D.mahalingam-dutt-dcops-vxlan], NVGRE
   [I-D.sridharan-virtualization-nvgre] and Virtual Machine Mobility in
   L3 networks[I-D.wkumari-dcops-l3-vmmobility].


7.  Further Work

   It is believed that overlay-based approaches may be able to reduce
   the overall amount of flooding and other multicast and broadcast
   related traffic (e.g, ARP and ND) currently experienced within
   current data centers with a large flat L2 network.  Further analysis
   is needed to characterize expected improvements.


8.  Summary

   This document has argued that network virtualization using L3
   overlays addresses a number of issues being faced as data centers
   scale in size.  In addition, careful consideration of a number of
   issues would lead to the development of interoperable implementation
   of virtualization overlays.


9.  Acknowledgments

   Helpful comments and improvements to this document have come from
   Ariel Hendel, Vinit Jain, and Benson Schliesser.


10.  IANA Considerations

   This memo includes no request to IANA.


11.  Security Considerations

   TBD






Narten, et al.             Expires May 3, 2012                 [Page 15]

Internet-Draft     Overlays for Network Virtualization      October 2011


12.  Informative References

   [I-D.eastlake-trill-rbridge-fine-labeling]
              Eastlake, D., Zhang, M., Agarwal, P., Dutt, D., and R.
              Perlman, "RBridges: Fine-Grained Labeling",
              draft-eastlake-trill-rbridge-fine-labeling-02 (work in
              progress), October 2011.

   [I-D.hasmit-otv]
              Grover, H., Rao, D., Farinacci, D., and V. Moreno,
              "Overlay Transport Virtualization", draft-hasmit-otv-03
              (work in progress), July 2011.

   [I-D.ietf-6man-udpzero]
              Fairhurst, G. and M. Westerlund, "IPv6 UDP Checksum
              Considerations", draft-ietf-6man-udpzero-04 (work in
              progress), October 2011.

   [I-D.ietf-lisp]
              Farinacci, D., Fuller, V., Meyer, D., and D. Lewis,
              "Locator/ID Separation Protocol (LISP)",
              draft-ietf-lisp-15 (work in progress), July 2011.

   [I-D.mahalingam-dutt-dcops-vxlan]
              Mahalingam, M., Dutt, D., Duda, K., Agarwal, P., Kreeger,
              L., Sridhar, T., Bursell, M., and C. Wright, "VXLAN: A
              Framework for Overlaying Virtualized Layer 2 Networks over
              Layer 3 Networks", draft-mahalingam-dutt-dcops-vxlan-00
              (work in progress), August 2011.

   [I-D.sridharan-virtualization-nvgre]
              Sridharan, M., Duda, K., Ganga, I., Greenberg, A., Lin,
              G., Pearson, M., Thaler, P., Tumuluri, C., Venkataramaiah,
              N., and Y. Wang, "NVGRE: Network Virtualization using
              Generic Routing Encapsulation",
              draft-sridharan-virtualization-nvgre-00 (work in
              progress), September 2011.

   [I-D.wkumari-dcops-l3-vmmobility]
              Kumari, W. and J. Halpern, "Virtual Machine mobility in L3
              Networks.", draft-wkumari-dcops-l3-vmmobility-00 (work in
              progress), August 2011.

   [RFC2661]  Townsley, W., Valencia, A., Rubens, A., Pall, G., Zorn,
              G., and B. Palter, "Layer Two Tunneling Protocol "L2TP"",
              RFC 2661, August 1999.

   [RFC2784]  Farinacci, D., Li, T., Hanks, S., Meyer, D., and P.



Narten, et al.             Expires May 3, 2012                 [Page 16]

Internet-Draft     Overlays for Network Virtualization      October 2011


              Traina, "Generic Routing Encapsulation (GRE)", RFC 2784,
              March 2000.

   [RFC2890]  Dommety, G., "Key and Sequence Number Extensions to GRE",
              RFC 2890, September 2000.

   [RFC5213]  Gundavelli, S., Leung, K., Devarapalli, V., Chowdhury, K.,
              and B. Patil, "Proxy Mobile IPv6", RFC 5213, August 2008.

   [RFC5844]  Wakikawa, R. and S. Gundavelli, "IPv4 Support for Proxy
              Mobile IPv6", RFC 5844, May 2010.

   [RFC5845]  Muhanna, A., Khalil, M., Gundavelli, S., and K. Leung,
              "Generic Routing Encapsulation (GRE) Key Option for Proxy
              Mobile IPv6", RFC 5845, June 2010.

   [RFC6245]  Yegani, P., Leung, K., Lior, A., Chowdhury, K., and J.
              Navali, "Generic Routing Encapsulation (GRE) Key Extension
              for Mobile IPv4", RFC 6245, May 2011.

   [RFC6325]  Perlman, R., Eastlake, D., Dutt, D., Gai, S., and A.
              Ghanwani, "Routing Bridges (RBridges): Base Protocol
              Specification", RFC 6325, July 2011.


Authors' Addresses

   Thomas Narten (editor)
   IBM

   Email: narten@us.ibm.com


   Murari Sridharan
   Microsoft

   Email: muraris@microsoft.com


   Dinesh Dutt
   Cisco

   Email: ddutt@cisco.com








Narten, et al.             Expires May 3, 2012                 [Page 17]

Internet-Draft     Overlays for Network Virtualization      October 2011


   David Black
   EMC

   Email: david.black@emc.com


   Lawrence Kreeger
   Cisco

   Email: kreeger@cisco.com









































Narten, et al.             Expires May 3, 2012                 [Page 18]


Html markup produced by rfcmarkup 1.108, available from http://tools.ietf.org/tools/rfcmarkup/