     Network Working Group                                 J. Parello
     Internet-Draft                                         B. Claise
     Intended Status: Standards Track             Cisco Systems, Inc.
     Expires: September 10, 2011                       March 10, 2011
     
     
     
                    Energy-aware Networks and Devices MIB
                     draft-ietf-eman-energy-aware-mib-01
     
     
     Status of this Memo
     
        This Internet-Draft is submitted to IETF in full conformance
        with the provisions of BCP 78 and BCP 79.
     
        Internet-Drafts are working documents of the Internet
        Engineering Task Force (IETF), its areas, and its working
        groups.  Note that other groups may also distribute working
        documents as Internet-Drafts.
     
        Internet-Drafts are draft documents valid for a maximum of six
        months and may be updated, replaced, or obsoleted by other
        documents at any time.  It is inappropriate to use Internet-
        Drafts as reference material or to cite them other than as
        "work in progress."
     
        The list of current Internet-Drafts can be accessed at
        http://www.ietf.org/ietf/1id-abstracts.txt
     
        The list of Internet-Draft Shadow Directories can be accessed
        at http://www.ietf.org/shadow.html
     
        This Internet-Draft will expire on September, 2011.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <Parello, Claise>     Expires September 10 2011          [Page 1]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     Copyright Notice
     
        Copyright (c) 2011 IETF Trust and the persons identified as the
        document authors.  All rights reserved.
     
        This document is subject to BCP 78 and the IETF Trust's Legal
        Provisions Relating to IETF Documents
        (http://trustee.ietf.org/license-info) in effect on the date of
        publication of this document.  Please review these documents
        carefully, as they describe your rights and restrictions with
        respect to this document.  Code Components extracted from this
        document must include Simplified BSD License text as described
        in Section 4.e of the Trust Legal Provisions and are provided
        without warranty as described in the Simplified BSD License.
     
     
     Abstract
     
        This document defines a subset of the Management Information
        Base (MIB) for power and energy monitoring of devices.  The
        module addresses devices identification, context information,
        and the relationship between reporting devices, remote devices,
        and monitoring probes.
     
     Conventions used in this document
     
       The key words "MUST", "MUST NOT", "REQUIRED", "SHALL",
       "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT
       RECOMMENDED", "MAY", and "OPTIONAL" in this document are to
       be interpreted as described in RFC 2119 [RFC2119].
     
     
     
     Table of Contents
     
        1. Introduction.............................................. 3
           1.1. Energy Management Document Overview.................. 4
        2. The Internet-Standard Management Framework................ 4
        3. Use Cases................................................. 5
        4. Terminology............................................... 5
        5. Architecture Concepts Applied to the MIB Module........... 5
           5.1 Power Monitor Information............................. 7
              5.1.1. Power Monitor Name.............................. 7
              5.1.2. Power Monitor Meter Domain...................... 8
              5.1.3. Alternate Key................................... 8
              5.1.4. Persistence..................................... 8
           5.2 Links to other MIB Modules............................ 9
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 2]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
           5.3 Power Monitor Parent and Child........................ 9
           5.4 Power Monitor Context................................ 10
        6. Structure of the MIB..................................... 10
        7. MIB Definitions.......................................... 10
        8. Security Considerations.................................. 23
        9. IANA Considerations...................................... 24
        10. References.............................................. 25
           10.1. Normative References............................... 25
           10.2. Informative References............................. 26
        11. Acknowledgments......................................... 26
     
     
        OPEN ISSUES:
     
        1. Length and format of PowerMonitorId. The pmPowerMonitorID
          should be a unique id that identfies the device in the
          universe. A UUID using RFC 4122 seems to suffice. However an
          x.509 certificate conforming to RFC 5280 could also be
          appropriate. We have specified the field as variable 16 bytes
          but would like feedback and consensus on the format that is
          appropriate.
        2. Do we want separate tables, as depicted in figure 1, as
          opposed to a single pmTable?
        3. Should the pmMgmtMacAddress, pmMgmtAddress,
          pmMgmtAddressType, and pmMgmtDNSName also be implemented for
          Power Monitor Parent?
     
     
     
     1. Introduction
     
        The EMAN standards provides network administrators with energy
        management. This document defines a subset of the Management
        Information Base (MIB) for use with network management protocols
        for power and energy monitoring of network devices and devices
        attached to the network, as specified in the Power Management
        Architecture [EMAN-FMWK], which in turn, is based on the Power
        Monitoring Requirements [EMAN-REQ].
     
        This module's special focus is on monitoring energy-aware
        networks and devices.  The module addresses device
        identification, context information, and relationships between
        reporting devices, remote devices, and monitoring probes.
     
        Devices and their sub-components may be characterized by the
        power-related attributes of a physical entity present in the
        ENTITY MIB [RFC4133], even though ENTITY MIB compliance is not a
     
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 3]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        requirement due to the variety and broad base of devices
        concerned with energy management.
     
     1.1. Energy Management Document Overview
     
        This document, which specifies the Energy-aware Networks and
        Devices MIB document is based on the Energy Management Framework
        [EMAN-FMWK], per the Energy Management requirements specified in
        [EMAN-REQ], which allows networks and devices to become energy
        aware.
     
        The Power and Energy Monitoring MIB [EMAN-MON-MIB] contains the
        managed objects for monitoring of power states and energy
        consumption/production.  The monitoring of power states
        includes: retrieving power states, properties of power states,
        current power state, power state transitions, and power state
        statistics. This MIB provides the detailed properties of the
        actual energy rate (power) and of accumulated energy, along with
        the power quality.
     
        The applicability statement document [EMAN-AS] provides the list
        of use cases, cross-reference between existing standards and the
        EMAN standard, and shows how the EMAN framework relates to other
        frameworks.
     
        EDITOR'S NOTE: [EMAN-MON-MIB] and [EMAN-AS] are not EMAN working
        group documents.  Hence, these references will be changed in the
        future.
     
     
     2. The Internet-Standard Management Framework
     
        For a detailed overview of the documents that describe the
        current Internet-Standard Management Framework, please refer to
        section 7 of RFC 3410 [RFC3410].
     
        Managed objects are accessed via a virtual information store,
        termed the Management Information Base or MIB.  MIB objects are
        generally accessed through the Simple Network Management
        Protocol (SNMP).  Objects in the MIB are defined using the
        mechanisms defined in the Structure of Management Information
        (SMI).  This memo specifies MIB modules that are compliant with
        SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58,
        RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580].
     
     
     
     
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 4]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     3. Use Cases
     
        Requirements for power and energy monitoring for networking
        devices are specified in [EMAN-REQ].  The requirements in [EMAN-
        REQ] cover devices typically found in communications networks,
        such as switches, routers, and various connected endpoints.  For
        a power monitoring architecture to be useful, it should also
        apply to facility meters, power distribution units, gateway
        proxies for commercial building control, home automation
        devices, and devices that interface with the utility and/or
        smart grid.  Accordingly, the scope of the MIB modules in this
        document is broader than that specified in [EMAN-REQ].
     
     
     4. Terminology
     
       The definitions of basic terms like Energy Management, Energy
       Monitoring, "Power, Energy, and Energy Consumption", Power
       Monitor, Power Monitor Parent, Power Monitor Child, Power
       Monitor Meter Domain, Power Level, and Manufacturer Power Level,
       Nameplate Power, Power Proxy, Power Aggregator, Power
       Distributor can be found in the Power Management Architecture
       [EMAN-FMWK].
     
       EDITOR'S NOTE: not sure if all terms will be used in the final
       version of the draft
     
       EDITOR'S NOTE: [EMAN-FMWK] is an informational non normative
       reference. Is this fine?
     
     
     5. Architecture Concepts Applied to the MIB Module
     
        This section describes the basic concepts specified in the Power
        Monitor Architecture [EMAN-FMWK], with specific information
        related to the MIB module specified in this document
     
        The following diagram shows the relationship of the identifying
        information.
     
     
     
     
     
     
     
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 5]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
                                        +-------------------------+
                                        | _Child Specific Info __ |
        +--------------------------+    |                         |
        |    Context Information   |    |  pmParentId             |
        | _______________________  |    |  pmParentProxyAbilities |
        |  pmRoleDescription       |    | _pmMgmtMacAddress       |
        |  pmKeywords              |    |  pmMgmtAddress          |
        |  pmImportance            |    |  pmMgmtAddressType      |
        |  pmCategory              |    |  pmMgmtDNSName          |
        +--------------------------+    +-------------------------+
                  |                            |
                  |                            |
                  |                            |
                  v                            v
          +-----------------------------------------+
          |  Power Monitor Information              |
          |_______________________________________  |
          | pmIndex                                 |
          | pmPowerMonitorId                        |
          | pmName                                  |
          | pmDomainName                            |
          | pmAlternateKey                          |
          +-----------------------------------------+
                  ^
                  |
                  |
                  |
        +--------------------------+
        |    Links to other MIBs   |
        | _______________________  |
        |  pmPhysicalEntity (*)    |
        |  pmEthPortIndex (**)     |
        |  pmEthPortGrpIndex (**)  |
        |  pmLldpPortNumber (***)  |
        +--------------------------+
     
          (*)   Link with the ENTITY MIB [RFC4133]
          (**)  Link with the Power over Ethernet MIB [RFC3621]
          (***) Link with LLDP MIBs [LLDP-MIB] [LLDP-MED-MIB]
     
                         Figure 1: MIB Objects Grouping
     
     
        As displayed in figure 1, there are four different types of MIB
        objects in the ENERGY-AWARE-MIB module:
     
        1) The Power Monitor Information. See Section 5.1 Power Monitor
          Information
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 6]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        2) The links to other MIB modules. See Section 5.2 Links to
          other MIB Modules
        3) The Power Monitor Child specific information. See Section 5.3
          Power Monitor Parent and Child
        4) The Context Information. See Section 5.4 Power Monitor
          Context
     
     
     5.1 Power Monitor Information
     
        Refer to the "Power Monitor Information" section in [EMAN-FMWK]
        for background information.  An energy aware device is
        considered an instance of a Power Monitor as defined in the
        [EMAN-FMWK].
     
        The Power Monitor information is specified in the MIB module
        pmTable table.  Every Power Monitor and MUST HAVE a unique Power
        Monitor index pmIndex.
        The pmIndex is a unique index greater than zero for each Power
        Monitor.  It is recommended that values be assigned sequentially
        starting from 1.
     
        The pmIndex is completed by the Power Monitor Universally Unique
        Identifier [RFC4122] in the pmPowerMonitorId MIB object.
     
     
     5.1.1. Power Monitor Name
     
        Every Power Monitor SHOULD have a printable name pmName.
        Possible pmName conventions are: textual DNS name, MAC-address
        of the device, interface ifName, or a text string uniquely
        identifying the Power Monitor.  However, if entPhysicalName is
        present for the respective pmPhysicalEntity (i.e. if the ENTITY-
        MIB [RFC4133] is supported), then the pmName SHOULD be identical
        to the entPhysicalName.  The pmName SHOULD be unique in the
        Power Monitor Meter Domain.  As an example, in the case of IP
        phones, pmName can be the device DNS name, while in the case of
        router/switch line cards, the pmName should contain the
        entPhysicalName.
     
     To distinguish if a Power Monitor is considered producing,
     consuming or metering power, the pmPowerCategory MIB object must be
     implemented.
     
     
     
     
     
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 7]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     5.1.2. Power Monitor Meter Domain
     
     
        Refer to the "Power Monitor Meter Domain" section in [EMAN-FMWK]
        for background information.
     
        When a Power Monitor Parent acts as a Power Aggregator or a
        Power Proxy, the Power Monitor Parent and its Power Monitor
        Child/Children MUST be a member of Power Monitor Meter Domain,
        specified by the pmDomainName MIB Object.  The pmDomainName,
        which is part of the pmTable, is a read-write MIB object.  Note
        that the Power Monitor MUST belong to a single Power Monitor
        Meter Domain.
     
        The Power Monitor Meter Domain SHOULD map 1-1 with a metered or
        sub-metered portion of the site.  The Power Monitor Meter Domain
        MUST be configured on the Power Monitor Parent.  The Power
        Monitor Children MAY inherit their domain values from the Power
        Monitor Parent or the Power Monitor Meter Domain MAY be
        configured directly in a Power Monitor Child.
     
     
     5.1.3. Alternate Key
     
        The pmAlternateKey object specifies a manufacturer defined
        string that can be used to identify the Power Monitor. Since
        Energy Management Systems (EMS) and Network Management Systems
        (NMS) may need to correlate objects across management systems,
        this alternate key is provided to provide such a link. This
        optional value is intended as a foreign key or alternate
        identifier for a manufacturer or EMS/NMS to use to correlate the
        unique Power Monitor Id in other systems or namespaces. If an
        alternate key is not available or is not applicable then NULL
        should be returned.
     
     
     5.1.4. Persistence
     
     
        In some situations, the Power Monitor information should be
        persistent across a reload.  For example, in a static setup
        where a switch monitors a series of connected PoE phones, there
        is a clear benefit for the NMS if the pmIndex and all associated
        information persist, as it saves a network discovery.  However,
        in other situations, such as a wireless access point monitoring
        the mobile user PCs, there is not much advantage to persist the
        Power Monitor Information. Therefore, a specific MIB object, the
        pmTablePersistence, enables and disables the persistence
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 8]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        globally for all Power Monitors information in the ENERGY-AWARE-
        MIB MIB module.
     
     5.2 Links to other MIB Modules
     
     
        The Power Monitor MUST contain the entityPhysicalIndex from the
        ENTITY MIB [RFC4133] in the pmPhysicalEntity, if supported by
        the Power Monitor.  In case of Power over Ethernet (if the Power
        over Ethernet MIB [RFC3621] is supported on the Power Monitor),
        the Power Monitor pmethPortIndex and pmethPortGrpIndex MUST
        contain the values of pethPsePortIndex and
        pethPsePortGroupIndex, respectively.  In case of LLDP-MED (if
        the LLDP-MED MIB is supported on the Power Monitor), the Power
        Monitor pmLldpPortNumber MUST contain the lldpLocPortNum from
        the LLDP MIB [LLDP-MIB].
     
     
     5.3 Power Monitor Parent and Child
     
        Refer to the "Power Monitor Parent and Child" section in [EMAN-
        FMWK] for background information.  In order to link the Power
        Monitor Child and the Power Monitor Parent, the pmParentId is
        introduced.
     
        The pmParentId, pmParentProxyAbilities, pmMgmtMacAddress,
        pmMgmtAddress, pmMgmtAddressType, and pmMgmtDNSName MIB objects
        are specific to Power Monitor Children.
     
        The Power Monitor Child MUST set the pmParentId content to its
        Power Monitor Parent pmIndex.  In the case of Power Monitor
        Parent, the pmParentId MUST be set to the null string
     
        The Power Monitor Child can indicate that it wants its Power
        Monitor Parent to proxy capabilities such as, energy reporting,
        power state configurations, non physical wake capabilities (such
        as WoL)), or any combination of capabilities. These capalities
        are indicated in the pmPArentProxyAbilities object. In the case
        of Power Monitor Parent, the pmParentProxyAbilities MUST be set
        to "none" (0).
     
        Since the communication between the Power Monitor Parent and
        Power Monitor Child is out of the scope, a Power Monitor Child
        can have additional objects used for easier identification by
        the NMS: IP Address and DNS name.   The MAC address is also
        provided as a way to identify the Power Monitor Child: this
        information is required, among other use case, by the wake on
        lan feature.
     
     
     <Parello, Claise>     Expires September 10, 2011          [Page 9]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     
     
     
       5.4 Power Monitor Context
     
        Refer to the "Power Monitor Context" section in [EMAN-FMWK] for
        background information.
     
        A Power Monitor can provide a pmImportance value in the range of
        1..100 to help differentiate the use or relative value of the
        device.  The importance range is from 1 (least important) to 100
        (most important).  The default importance value is 1.
     
        A Power Monitor can provide a set of pmKeywords.  These keywords
        are a list of tags that can be used for grouping and summary
        reporting within or between Power Monitor Meter Domains.
     
        Additionally, a Power Monitor can provide a pmRoleDescription
        string that indicates the purpose the Power Monitor serves in
        the network or for the site/business.
     
     6. Structure of the MIB
     
        The primary MIB object in this MIB module is the
        EnergyAwareDeviceMIBObject.  The pmTable table of
        EnergyAwareDeviceMIBObject describes an entity in the network
        that is a Power Monitor according the [EMAN-FMWK].
     
        A Power Monitor that implements the EnergyAwareDeviceMIB
        contains information describing itself as an entity in the
        context of the network (such as its Power Monitor Meter Domain
        pmDomainName) and attributes for describing its business context
        (such as pmImportance, pmRoleDescription and pmKeywords).
     
        The information in this MIB describes the device itself so that
        the device is aware of its context in a communication network
        with respect to power.  The actual power usage, which is
        described in [EMAN-FMWK], is specified in [EMAN-MON-MIB].
     
     
     7. MIB Definitions
     
     
        -- ************************************************************
        --
        --
        -- This MIB is used to monitor power usage of network
        -- devices
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 10]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        --
        -- *************************************************************
     
        ENERGY-AWARE-MIB DEFINITIONS ::= BEGIN
     
        IMPORTS
            MODULE-IDENTITY,
            OBJECT-TYPE,
            mib-2,
            Integer32
                FROM SNMPv2-SMI
            TEXTUAL-CONVENTION, MacAddress, TruthValue
                FROM SNMPv2-TC
            MODULE-COMPLIANCE,
            OBJECT-GROUP
                FROM SNMPv2-CONF
            SnmpAdminString
                FROM SNMP-FRAMEWORK-MIB
            InetAddressType, InetAddress
               FROM INET-ADDRESS-MIB
            PhysicalIndexOrZero
               FROM ENTITY-MIB;
     
     
     
        energyAwareMIB MODULE-IDENTITY
            LAST-UPDATED    "201103050000Z"
            ORGANIZATION    "IETF EMAN Working Group"
            CONTACT-INFO
               "WG Charter:
                http://datatracker.ietf.org/wg/eman/charter/
     
               Mailing Lists:
                General Discussion: eman@ietf.org
                To Subscribe: https://www.ietf.org/mailman/listinfo/eman
                Archive: http://www.ietf.org/mail-archive/web/eman
     
               Editors:
                  John Parello
                  Cisco Systems, Inc.
                  3550 Cisco Way
                  San Jose, California 95134
                  US
                  Phone: +1 408 525 2339
                  Email: jparello@cisco.com
     
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 11]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
                  Benoit Claise
                  Cisco Systems, Inc.
                  De Kleetlaan 6a b1
                  Degem 1831
                  Belgium
                  Phone:  +32 2 704 5622
                  Email: bclaise@cisco.com"
     
            DESCRIPTION
               "This MIB is used to monitor power and energy in
               devices."
            REVISION
                "201103050000Z"
            DESCRIPTION
               "Initial version, published as RFC XXXX."
     
     
           ::= { mib-2 xxxxx }
     
        energyAwareMIBNotifs OBJECT IDENTIFIER
            ::= { energyAwareMIB 0 }
     
        energyAwareMIBObjects OBJECT IDENTIFIER
            ::= { energyAwareMIB 2 }
     
        energyAwareMIBConform  OBJECT IDENTIFIER
            ::= { energyAwareMIB 3 }
     
     
        -- Textual Conventions
     
        PowerMonitorId ::= TEXTUAL-CONVENTION
            STATUS          current
            DESCRIPTION
             "This object indicates the Power Monitor Universally
             Unique Identifier."
            REFERENCE
                   "IETF RFC 4122"
            SYNTAX          OCTET STRING (SIZE (16))
     
        PethPsePortIndexOrZero ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d"
           STATUS            current
           DESCRIPTION
               "This textual convention is an extension of the
               pethPsePortIndex convention, which defines a greater than
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 12]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
               zero value used to identify a power Ethernet PSE port.
               This extension permits the additional value of zero.  The
               semantics of the value zero are object-specific and must,
               therefore, be defined as part of the description of any
               object that uses this syntax.  Examples of the usage of
               this extension are situations where none or all physical
               entities need to be referenced."
           SYNTAX Integer32 (0..2147483647)
     
        PethPsePortGroupIndexOrZero::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d"
           STATUS            current
           DESCRIPTION
               "This textual convention is an extension of the
               pethPsePortGroupIndex convention, which defines a greater
               than zero value used to identify group containing the
               port to which a power Ethernet PSE is connected.  This
               extension permits the additional value of zero.  The
               semantics of the value zero are object-specific and must,
               therefore, be defined as part of the description of any
               object that uses this syntax.  Examples of the usage of
               this extension are situations where none or all physical
               entities need to be referenced."
           SYNTAX Integer32 (0..2147483647)
     
      LldpPortNumberOrZero ::= TEXTUAL-CONVENTION
           DISPLAY-HINT "d"
           STATUS     current
           DESCRIPTION
               "This textual convention is an extension of the
               LldpPortNumber convention specified in the LLDP MIB,
               which defines a greater than zero value used to uniquely
               identify each port contained in the chassis (that is
               known to the LLDP agent) by a port number.  This
               extension permits the additional value of zero. The
               semantics of the value zero are object-specific and must,
               therefore, be defined as part of the description of any
               object that uses this syntax.  Examples of the usage of
               this extension are situations where none or all physical
               entities need to be referenced."
          SYNTAX Integer32(0..4096)
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 13]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
       PowerMonitorKeywordList ::= TEXTUAL-CONVENTION
           STATUS          current
           DESCRIPTION
               "A list of keywords that can be used to group Power
               Monitors for reporting or searching. If multiple keywords
               are present, then this string will contain all the
               keywords separated by the ',' character. For example, if
               a Power Monitor were to be tagged with the keyword values
               'hospitality' and 'guest', then the keyword list will be
               'hospitality,guest'."
           SYNTAX OCTET STRING (SIZE (0..255))
     
        -- Objects
     
        pmTablePersistence OBJECT-TYPE
            SYNTAX          TruthValue
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
               "This object enables/disables persistence for
               all entries in the pmTable. A value of True enables the
               persistence, while a value of False disables the
               persistence."
            ::= { energyAwareMIBObjects 1 }
     
     
        pmTable OBJECT-TYPE
            SYNTAX          SEQUENCE OF PmEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
               "This table lists Power Monitors."
            ::= { energyAwareMIBObjects 2 }
     
     
        pmEntry OBJECT-TYPE
            SYNTAX          PmEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
               "An entry describes the attributes of a Power Monitor.
               Whenever a new Power Monitor is added or deleted a row in
               the pmTable is added or deleted."
            INDEX           { pmIndex }
            ::= { pmTable 1 }
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 14]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     
        PmEntry ::= SEQUENCE {
                pmIndex                     Integer32,
                pmPowerMonitorId            PowerMonitorId,
                pmPhysicalEntity            PhysicalIndexOrZero,
                pmEthPortIndex              PethPsePortIndexOrZero,
                pmEthPortGrpIndex           PethPsePortGroupIndexOrZero,
                pmLldpPortNumber            LldpPortNumberOrZero,
                pmName                      SnmpAdminString,
                pmDomainName                SnmpAdminString,
                pmRoleDescription           SnmpAdminString,
                pmMgmtMacAddress            MacAddress,
                pmMgmtAddressType           InetAddressType,
                pmMgmtAddress               InetAddress,
                pmMgmtDNSName               SnmpAdminString,
                pmAlternateKey              SnmpAdminString,
                pmKeywords                  PowerMonitorKeywordList,
                pmImportance                Integer32,
                pmPowerCategory             INTEGER,
                pmParentId                  PowerMonitorId,
                pmParentProxyAbilities      BITS
        }
     
        pmIndex OBJECT-TYPE
            SYNTAX          Integer32 (1..2147483647)
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
               "A unique value, greater than zero, for each Power
               Monitor. It is recommended that values be assigned
               sequentially starting from 1.  The value for each pmIndex
               must remain constant at least from one re-initialization
               of the entity's network management system to the next re-
               initialization."
             ::= { pmEntry 1 }
     
        pmPowerMonitorId OBJECT-TYPE
            SYNTAX          PowerMonitorId
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
               "This object indicates the Power Monitor UUID
               identifier."
            ::= { pmEntry 2 }
     
        pmPhysicalEntity OBJECT-TYPE
            SYNTAX          PhysicalIndexOrZero
            MAX-ACCESS      read-only
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 15]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
            STATUS          current
            DESCRIPTION
               "This object contains the index of a physical entity in
               the ENTITY MIB [RFC4133].  This physical entity is the
               given observation point.  If such a physical entity
               cannot be specified or is not known then the object is
               zero."
            ::= { pmEntry 3 }
     
        pmEthPortIndex   OBJECT-TYPE
            SYNTAX       PethPsePortIndexOrZero
            MAX-ACCESS   read-only
            STATUS       current
            DESCRIPTION
               "This variable uniquely identifies the power Ethernet
               port to which the attached device is connected [RFC3621].
               If such a power Ethernet port cannot be specified or is
               not known then the object is zero."
            ::= { pmEntry 4 }
     
        pmEthPortGrpIndex   OBJECT-TYPE
            SYNTAX       PethPsePortGroupIndexOrZero
            MAX-ACCESS   read-only
            STATUS       current
            DESCRIPTION
               "This variable uniquely identifies the group containing
               the port to which a power Ethernet PSE is connected
               [RFC3621].  If such a group cannot be specified or is not
               known then the object is zero."
            ::= { pmEntry 5 }
     
        pmLldpPortNumber   OBJECT-TYPE
            SYNTAX       LldpPortNumberOrZero
            MAX-ACCESS   read-only
            STATUS       current
            DESCRIPTION
              "This variable uniquely identifies the port component
              (contained in the local chassis with the LLDP agent) as
              defined by the lldpLocPortNum in the [LLDP-MIB] and
              [LLDP-MED-MIB]. If such a port number cannot be specified
              or is not known then the object is zero."
           ::= { pmEntry 6 }
     
        pmName OBJECT-TYPE
            SYNTAX          SnmpAdminString
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 16]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
               "This object specifies a printable name, a text string,
               for the Power Monitor. The pmName SHOULD be unique. If
               pmPhysicalName is present for the respective
               pmPhysicalEntity (i.e. if the ENTITY-MIB [RFC4133] is
               supported), then the pmName SHOULD be identical to the
               pmPhysicalName. If pmPhysicalName is not present, the
               process to assign the pmName can be implementation
               specific. Example: DNS Name, MAC address in canonical
               form, ifName, etc.
               However, if pmPhysicalName is present for the respective
               pmPhysicalEntity (i.e. if the ENTITY-MIB [RFC4133] is
               supported), then the pmName should be identical to the
               pmPhysicalName."
            ::= { pmEntry 7 }
     
        pmDomainName OBJECT-TYPE
            SYNTAX          SnmpAdminString
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
               "This object specifies the name of a Power Monitor Meter
               Domain for the Power Monitor.  This object specifies a
               null string if no Power Monitor Domain name is
               configured. The value of pmDomainName must remain
               constant at least from one re-initialization of the
               entity's network management system to the next re-
               initialization."
            ::= { pmEntry 8 }
     
        pmRoleDescription OBJECT-TYPE
            SYNTAX          SnmpAdminString
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
               "This object specifies an administratively assigned name
               to indicate the purpose a Power Monitor serves in the
               network.
     
               For example, we can have a phone deployed to a lobby with
               pmRoleDescription as 'Lobby IP phone'.
     
               This object specifies a null string if no role
               description is configured."
            ::= { pmEntry 9 }
     
        pmMgmtMacAddress OBJECT-TYPE
            SYNTAX          MacAddress
            MAX-ACCESS      read-only
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 17]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
            STATUS          current
            DESCRIPTION
               "This object specifies a MAC address of the Power
               Monitor. This object only applies to Power Monitor
               Children. For a Power Monitor Parent, the value SHOULD be
               set to the null string."
            ::= { pmEntry 10 }
     
     
     
        pmMgmtAddressType OBJECT-TYPE
            SYNTAX          InetAddressType
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
              "This object specifies the pmMgmtAddress type, i.e. an
              IPv4 address or an IPv6 address. This object only applies
              to a Power Monitor Children. For a Power Monitor only
              Parent, the value SHOULD be set to unknown(0)."
            ::= { pmEntry 11 }
     
        pmMgmtAddress OBJECT-TYPE
            SYNTAX          InetAddress
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
               "This object specifies the management address as an IPv4
               address or IPv6 address of Power Monitor. The IP address
               type, i.e. IPv4 or IPv6, is determined by the
               pmMgmtAddressType value. This object only applies to a
               Power Monitor Children. For a Power Monitor, the value
               SHOULD be set to the null string."
            ::= { pmEntry 12 }
     
        pmMgmtDNSName OBJECT-TYPE
            SYNTAX          SnmpAdminString
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
               "This object specifies the DNS name of the pmMgmtAddress.
               This object only applies to a Power Monitor Children. For
               a Power Monitor Parent, the value SHOULD be set to the
               null string."
            ::= { pmEntry 13 }
     
        pmAlternateKey OBJECT-TYPE
            SYNTAX          SnmpAdminString
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 18]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
               "This object specifies a manufacturer defined string that
               can be used to identify the Power Monitor. Since Element
               Management Systems (EMS) and Network Management Systems
               (NMS) may need to correlate objects across management
               systems, this alternate key is provided to provide such a
               link. This optional value is intended as a foreign key or
               alternate identifier for a manufacturer or EMS/NMS to use
               to correlate the unique Power Monitor Id in other systems
               or namespaces. If an alternate key is not available or is
               not applicable then NULL should be returned."
            ::= { pmEntry 14 }
     
        pmKeywords OBJECT-TYPE
            SYNTAX          PowerMonitorKeywordList
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
              "This object specifies a list of keywords that can be
              used to group Power Monitors for reporting or searching.
              This object specifies the null string if no keywords have
              been configured. If multiple keywords are present, then
              this string will contain all the keywords separated by
              the ',' character. For example, if a Power Monitor were
              to be tagged with the keyword values 'hospitality' and
              'guest', then the keyword list will be
              'hospitality,guest'.
     
               If write access is implemented and a value is written
               into the instance, the agent must retain the supplied
               value in the pmKeywords instance associated with
               the same physical entity for as long as that entity
               remains instantiated.  This includes instantiations
               across all re-initializations/reboots of the network
               management system."
            ::= { pmEntry 15 }
     
        pmImportance OBJECT-TYPE
            SYNTAX          Integer32 (1..100)
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
               "This object specifies a ranking of how important the
               Power Monitor is (on a scale of 1 to 100) compared with
               other Power Monitors in the same Power Monitor Meter
               Domain. The ranking should provide a business or
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 19]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
               operational context for the Power Monitor as compared to
               other similar Power Monitors. This ranking could be used
               as input for policy-based network management.
     
     
               Although network managers must establish their own
               ranking, the following is a broad recommendation:
     
               90 to 100 Emergency response
               80 to 90 Executive or business critical
               70 to 79 General or Average
               60 to  69 Staff or support
               40 to  59 Public or guest
               1  to 39 Decorative or hospitality"
            DEFVAL          { 1 }
            ::= { pmEntry 16 }
     
        pmPowerCategory OBJECT-TYPE
            SYNTAX          INTEGER {
                                consumer(0),
                                provider(1),
                                meter(2)
                            }
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
               "This object describes the Power Monitor and indicates
               the expected power usage of the Power Monitor. A Power
               Monitor could be designed or manufactured to be a
               provider(1), consumer(0) or meter(2) of power.
     
               The actual power direction is indicated by the sign of
               pmPower, with positive representing consumption and
               negative representing production, and may or may not
               match the expected value of pmPowerCategory. In these
               cases the two objects can be used to detect unexpected
               conditions of the Power Monitor.
     
               For example a generator with a category of provider(1)
               that is malfunctioning and is consuming power as
               indicated by a positive pmPower value."
            ::= { pmEntry 17 }
     
        pmParentId OBJECT-TYPE
            SYNTAX       PowerMonitorId
            MAX-ACCESS   read-only
            STATUS       current
            DESCRIPTION
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 20]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
               "If the current Power Monitor has a Power Monitor Parent,
               then its Power Monitor Id value is set in pmParentId.
               This object only applies to Power Monitor Children. When
               the Power Monitor is a Power Monitor Parent, the
               pmParentId value MUST be set to the null string.
               "
            ::= { pmEntry 18 }
     
        pmParentProxyAbilities OBJECT-TYPE
            SYNTAX          BITS {
                                none(0),
                                report(1),
                                configuration(2),
                                wakeonlan(3)
                            }
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
               "This object describes the capabilities of the Power
               Monitor Parent (represented by the pmParentId) for the
               Power Monitor Child, represented by the pmIndex. This
               object only applies to a Power Monitor Child.
               None (0) MUST be used when the Power Monitor represented
               by the pmIndex is a Power Monitor Parent, and no other
               bit can be set.
               Report(1) indicates that the Power Monitor Parent reports
               the usage for the Power Monitor Child.
               Configuration(2) indicates that the Power Monitor Parent
               can configure the Power Level for the Power Monitor
               Child.
               Wakeonlan(3) indicates that the Power Monitor Parent can
               wake up the Power Monitor Child, whatever the mechanism."
            ::= { pmEntry 19 }
     
     
        -- Conformance
     
        energyAwareMIBCompliances  OBJECT IDENTIFIER
            ::= { energyAwareMIBObjects 3 }
     
        energyAwareMIBGroups  OBJECT IDENTIFIER
            ::= { energyAwareMIBObjects 4 }
     
     
        energyAwareMIBFullCompliance MODULE-COMPLIANCE
            STATUS          current
            DESCRIPTION
                "When this MIB is implemented with support for
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 21]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
                read-create, then such an implementation can
                claim full compliance. Such devices can then
                be both monitored and configured with this MIB."
            MODULE          -- this module
            MANDATORY-GROUPS {
                        energyAwareMIBTableGroup
                            }
     
            ::= { energyAwareMIBCompliances 1 }
     
        energyAwareMIBReadOnlyCompliance MODULE-COMPLIANCE
            STATUS          current
            DESCRIPTION
                "When this MIB is implemented without support for
                read-create (i.e. in read-only mode), then such an
                implementation can claim read-only compliance.  Such a
                device can then be monitored but can not be configured
                with this MIB."
            MODULE          -- this module
            MANDATORY-GROUPS {
                         energyAwareMIBTableGroup
                            }
     
            OBJECT          pmTablePersistence
            MIN-ACCESS      read-only
            DESCRIPTION
                "Write access is not required."
     
            OBJECT          pmName
            MIN-ACCESS      read-only
            DESCRIPTION
                "Write access is not required."
     
            OBJECT          pmDomainName
            MIN-ACCESS      read-only
            DESCRIPTION
                "Write access is not required."
     
            OBJECT          pmRoleDescription
            MIN-ACCESS      read-only
            DESCRIPTION
                "Write access is not required."
     
            OBJECT          pmKeywords
            MIN-ACCESS      read-only
            DESCRIPTION
            "Write access is not required."
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 22]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
            OBJECT          pmImportance
            MIN-ACCESS      read-only
            DESCRIPTION
                "Write access is not required."
     
        ::= { energyAwareMIBCompliances 2 }
     
        -- Units of Conformance
     
        energyAwareMIBTableGroup OBJECT-GROUP
            OBJECTS         {
                                -- Note that object pmIndex is NOT
                                -- included since it is not-accessible
                                pmTablePersistence,
                                pmPowerMonitorId,
                                pmPhysicalEntity,
                                pmEthPortIndex,
                                pmEthPortGrpIndex,
                                pmLldpPortNumber,
                                pmName,
                                pmDomainName,
                                pmRoleDescription,
                                pmMgmtMacAddress,
                                pmMgmtAddressType,
                                pmMgmtAddress,
                                pmMgmtDNSName,
                                pmAlternateKey,
                                pmKeywords,
                                pmImportance,
                                pmPowerCategory,
                                pmParentId,
                                pmParentProxyAbilities
                            }
            STATUS          current
            DESCRIPTION
                "This group contains the collection of all the objects
                related to the PowerMonitor."
            ::= { energyAwareMIBGroups 1 }
     
     
        END
     
     
     8. Security Considerations
     
        Some of the readable objects in these MIB modules (i.e., objects
        with a MAX-ACCESS other than not-accessible) may be considered
        sensitive or vulnerable in some network environments.  It is
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 23]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        thus important to control even GET and/or NOTIFY access to these
        objects and possibly to even encrypt the values of these objects
        when sending them over the network via SNMP.
     
        There are a number of management objects defined in these MIB
        modules with a MAX-ACCESS clause of read-write and/or read-
        create.  Such objects MAY be considered sensitive or vulnerable
        in some network environments.  The support for SET operations in
        a non-secure environment without proper protection can have a
        negative effect on network operations.  The following are the
        tables and objects and their sensitivity/vulnerability:
     
          . Unauthorized changes to the pmDomainName, pmName,
             pmRoleDescription, pmKeywords, and/or pmImportance MAY
             disrupt power and energy collection, and therefore any
             predefined policies defined in the network.
     
     
        SNMP versions prior to SNMPv3 did not include adequate security.
        Even if the network itself is secure (for example, by using
        IPsec), there is still no secure control over who on the secure
        network is allowed to access and GET/SET
        (read/change/create/delete) the objects in these MIB modules.
     
     
     
        It is RECOMMENDED that implementers consider the security
        features as provided by the SNMPv3 framework (see [RFC3410],
        section 8), including full support for the SNMPv3 cryptographic
        mechanisms (for authentication and privacy).
     
        Further, deployment of SNMP versions prior to SNMPv3 is NOT
        RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
        enable cryptographic security.  It is then a customer/operator
        responsibility to ensure that the SNMP entity giving access to
        an instance of these MIB modules is properly configured to give
        access to the objects only to those principals (users) that have
        legitimate rights to GET or SET (change/create/delete) them.
     
     
     9. IANA Considerations
     
        The MIB module in this document uses the following IANA-assigned
        OBJECT IDENTIFIER values recorded in the SMI Numbers registry:
     
          Descriptor                         OBJECT IDENTIFIER value
          ----------                         -----------------------
          energyAwareMIB                     { mib-2 xxx }
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 24]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     
        Additions to this MIB module are subject to Expert Review
        [RFC5226], i.e., review by one of a group of experts designated
        by an IETF Area Director.  The group of experts MUST check the
        requested MIB objects for completeness and accuracy of the
        description.  Requests for MIB objects that duplicate the
        functionality of existing objects SHOULD be declined.  The
        smallest available OID SHOULD be assigned to a new MIB objects.
        The specification of new MIB objects SHOULD follow the structure
        specified in Section 6 and MUST be published using a well-
        established and persistent publication medium.
     
     
     10. References
     
     10.1. Normative References
     
     
        [RFC2119] S. Bradner, Key words for use in RFCs to Indicate
                Requirement Levels, BCP 14, RFC 2119, March 1997.
     
        [RFC2578]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
                Schoenwaelder, Ed., "Structure of Management
                Information Version 2 (SMIv2)", STD 58, RFC 2578, April
                1999.
     
        [RFC2579]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
                Schoenwaelder, Ed., "Textual Conventions for SMIv2",
                STD 58, RFC 2579, April 1999.
     
        [RFC2580]  McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                "Conformance Statements for SMIv2", STD 58, RFC 2580,
                April 1999.
     
        [RFC3621] Berger, A., and D. Romascanu, "Power Ethernet MIB",
                RFC3621, December 2003.
     
        [RFC4122]  Leach, P., Mealling, M., and R. Salz, "A Universally
                Unique IDentifier (UUID) URN Namespace ", RFC 4122,
                July 2005.
     
        [RFC4133]  Bierman, A. and K. McCloghrie, "Entity MIB (Version
                3)", RFC 4133, August 2005.
     
        [LLDP-MIB] IEEE 802.1AB-2005, "Management Information Base
                module for LLDP configuration, statistics, local system
                data and remote systems data components", May 2005.
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 25]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
        [LLDP-MED-MIB]  ANSI/TIA-1057, "The LLDP Management Information
                Base extension module for TIA-TR41.4 media endpoint
                discovery information", July 2005.
     
        [EMAN-MON-MIB] Claise, B., Chandramouli, M., Parello, J., and
                Schoening, B., "Power and Energy Monitoring MIB",
                draft-claise-energy-monitoring-mib-06, (work in
                progress), October 2010.
     
     
     
     10.2. Informative References
     
     
     
        [RFC3410]  Case, J., Mundy, R., Partain, D., and B. Stewart,
                "Introduction and Applicability Statements for Internet
                Standard Management Framework ", RFC 3410, December
                2002.
     
        [RFC5226]  Narten, T. Alverstrand, H., A. and K. McCloghrie,
                "Guidelines for Writing an IANA Considerations Section
                in RFCs ", BCP 26, RFC 5226, May 2008.
     
        [EMAN-REQ] Quittek, J., Winter, R., Dietz, T., Claise, B., and
                M. Chandramouli, "Requirements for Power Monitoring",
                draft-ietf-eman-requirements-00 (work in progress),
                December 2010.
     
        [EMAN-FMWK] Claise, B., Parello, J., Schoening, B., and J.
                Quittek, draft-ietf-eman-framework-00, (work in
                progress), December 2010.
     
        [EMAN-AS] Tychon, E., Laherty, M., and B. Schoening, "Energy
                Management (EMAN) Applicability Statement", draft-
                tychon-eman-applicability-statement-00, (work in
                progress), October 2010
     
     
     
     
     11. Acknowledgments
     
        The authors would like to thank Juergen Quittek, Brad Schoening,
        and Mouli Chandramouli for their help, as well as Michael Brown
        for improving the text dramatically.
     
     
     
     
     <Parello, Claise>     Expires September 10, 2011         [Page 26]


     Internet-Draft <Energy-aware Networks and Devices MIB> Mar. 2011
     
     
     Authors' Addresses
     
      Benoit Claise
      Cisco Systems, Inc.
      De Kleetlaan 6a b1
      Diegem 1813
      BE
     
      Phone: +32 2 704 5622
      Email: bclaise@cisco.com
     
     
      John Parello
      Cisco Systems, Inc.
      3550 Cisco Way
      San Jose, California 95134
      US
     
      Phone: +1 408 525 2339
      Email: jparello@cisco.com
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     