draft-ietf-isis-gmpls-extensions-06.txt   draft-ietf-isis-gmpls-extensions-07.txt 
skipping to change at page 1, line 15 skipping to change at page 1, line 15
Expiration Date: July 2002 A. Banerjee (Calient Networks) Expiration Date: July 2002 A. Banerjee (Calient Networks)
J. Drake (Calient Networks) J. Drake (Calient Networks)
G. Bernstein (Ciena) G. Bernstein (Ciena)
D. Fedyk (Nortel Networks) D. Fedyk (Nortel Networks)
E. Mannie (GTS Network) E. Mannie (GTS Network)
D. Saha (Tellium) D. Saha (Tellium)
V. Sharma (Metanoia, Inc.) V. Sharma (Metanoia, Inc.)
IS-IS Extensions in Support of Generalized MPLS IS-IS Extensions in Support of Generalized MPLS
draft-ietf-isis-gmpls-extensions-06.txt draft-ietf-isis-gmpls-extensions-07.txt
1. Status of this Memo 1. Status of this Memo
This document is an Internet-Draft and is in full conformance with This document is an Internet-Draft and is in full conformance with
all provisions of Section 10 of RFC2026. all provisions of Section 10 of RFC2026.
Internet-Drafts are working documents of the Internet Engineering Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as Internet- other groups may also distribute working documents as Internet-
Drafts. Drafts.
skipping to change at page 6, line 16 skipping to change at page 6, line 16
When the Switching Capability field is PSC-1, PSC-2, PSC-3, or PSC-4, When the Switching Capability field is PSC-1, PSC-2, PSC-3, or PSC-4,
the specific information includes Interface MTU and Minimum LSP the specific information includes Interface MTU and Minimum LSP
Bandwidth. The Interface MTU is encoded as a two octets integer. The Bandwidth. The Interface MTU is encoded as a two octets integer. The
Minimum LSP Bandwidth is is encoded in a 4 octets field in the IEEE Minimum LSP Bandwidth is is encoded in a 4 octets field in the IEEE
floating point format. The units are bytes (not bits!) per second. floating point format. The units are bytes (not bits!) per second.
When the Switching Capability field is L2SC, there is no specific When the Switching Capability field is L2SC, there is no specific
information. information.
When the Switching Capability field is TDM, the specific information When the Switching Capability field is TDM, the specific information
includes Minimum LSP Bandwidth, which is is encoded in a 4 octets includes Minimum LSP Bandwidth, and an indication whether the
field in the IEEE floating point format. The units are bytes (not interface supports Standard or Arbitrary SONET/SDH. The Minimum LSP
bits!) per second. Bandwidth is encoded in a 4 octets field in the IEEE floating point
format. The units are bytes (not bits!) per second. The indication
whether the interface supports Standard or Arbitrary SONET/SDH is
encoded as 1 octet. The value of this octet is 0 if the interface
supports Standard SONET/SDH, and 1 if the interface supports
Arbitrary SONET/SDH.
When the Switching Capability field is LSC, there is no specific When the Switching Capability field is LSC, there is no specific
information. information.
The Interface Switching Capability Descriptor sub-TLV may occur more The Interface Switching Capability Descriptor sub-TLV may occur more
than once within the extended IS reachability TLV (this is needed to than once within the extended IS reachability TLV (this is needed to
handle interfaces that support multiple switching capabilities). handle interfaces that support multiple switching capabilities).
5.5. Shared Risk Link Group TLV 5.5. Shared Risk Link Group TLV
 End of changes. 

This html diff was produced by rfcdiff 1.23, available from http://www.levkowetz.com/ietf/tools/rfcdiff/