draft-ietf-roll-home-routing-reqs-05.txt | draft-ietf-roll-home-routing-reqs-06.txt | |||
---|---|---|---|---|
Networking Working Group A. Brandt | Networking Working Group A. Brandt | |||
Internet Draft Zensys, Inc. | Internet Draft Zensys, Inc. | |||
Intended status: Informational G. Porcu | Intended status: Informational G. Porcu | |||
Expires: May 2009 Telecom Italia | Expires: May 2009 Telecom Italia | |||
November 19, 2008 | November 19, 2008 | |||
Home Automation Routing Requirements in Low Power and Lossy | Home Automation Routing Requirements in Low Power and Lossy | |||
Networks | Networks | |||
draft-ietf-roll-home-routing-reqs-05 | draft-ietf-roll-home-routing-reqs-06 | |||
Status of this Memo | Status of this Memo | |||
By submitting this Internet-Draft, each author represents that | By submitting this Internet-Draft, each author represents that | |||
any applicable patent or other IPR claims of which he or she is | any applicable patent or other IPR claims of which he or she is | |||
aware have been or will be disclosed, and any of which he or she | aware have been or will be disclosed, and any of which he or she | |||
becomes aware will be disclosed, in accordance with Section 6 of | becomes aware will be disclosed, in accordance with Section 6 of | |||
BCP 79. | BCP 79. | |||
Internet-Drafts are working documents of the Internet Engineering | Internet-Drafts are working documents of the Internet Engineering | |||
skipping to change at page 4, line 51 | skipping to change at page 4, line 51 | |||
event. | event. | |||
The sensor may generate a trap message to notify a | The sensor may generate a trap message to notify a | |||
controller or directly activate an actuator. | controller or directly activate an actuator. | |||
If sufficiently powered, sensor nodes may | If sufficiently powered, sensor nodes may | |||
participate in routing network messages. | participate in routing network messages. | |||
Upstream: Data direction traveling from a PAN to a LAN | Upstream: Data direction traveling from a PAN to a LAN | |||
device. | device. | |||
Refer to the roll-terminology reference document for a full list | Refer to the roll-terminology reference document for a full list | |||
of terms used in the IETF ROLL WG. | of terms used in the IETF ROLL WG (I-D.draft-ietf-roll-terminology). | |||
1. Introduction | 1. Introduction | |||
This document presents home control and automation application | This document presents home control and automation application | |||
specific requirements for Routing Over Low power and Lossy | specific requirements for Routing Over Low power and Lossy | |||
networks (ROLL). In a modern home, a high number of wireless | networks (ROLL). In a modern home, a high number of wireless | |||
devices are used for a wide set of purposes. Examples include | devices are used for a wide set of purposes. Examples include | |||
actuators (relay, light dimmer, heating valve), sensors (wall | actuators (relay, light dimmer, heating valve), sensors (wall | |||
switch, water leak, blood pressure) and advanced controllers. | switch, water leak, blood pressure) and advanced controllers. | |||
Basic home control modules such as wall switches and plug-in | Basic home control modules such as wall switches and plug-in | |||
skipping to change at page 16, line 7 | skipping to change at page 16, line 7 | |||
When promoted to an RFC, the references MUST be updated to RFCs as | When promoted to an RFC, the references MUST be updated to RFCs as | |||
well or removed from the references section. | well or removed from the references section. | |||
9.1. Normative References | 9.1. Normative References | |||
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate | [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate | |||
Requirement Levels", BCP 14, RFC 2119, March 1997. | Requirement Levels", BCP 14, RFC 2119, March 1997. | |||
9.2. Informative References | 9.2. Informative References | |||
[I-D.draft-ietf-roll-indus-routing-reqs] | [I-D.draft-ietf-roll-terminology] | |||
"Industrial Routing Requirements in Low Power and Lossy | ||||
Networks", Kris Pister, Pascal Thubert, Sicco Dwars, | ||||
Tom Phinney, draft-ietf-roll-indus-routing-reqs-02 | ||||
(work in progress), October 2008 | ||||
[I-D.draft-ietf-roll-urban-routing-reqs] | ||||
"Urban WSNs Routing Requirements in Low Power and Lossy | ||||
Networks", Mischa Dohler, Thomas Watteyne, Tim Winter, | ||||
Dominique Barthel, Christian Jacquenet, | ||||
Giyyarpuram Madhusudan, Gabriel Chegaray, | ||||
draft-ietf-roll-urban-routing-reqs-02 (work in progress) | ||||
October 2008 | ||||
[I-D.draft-martocci-roll-building-routing-reqs] | ||||
"Building Automation Routing Requirements in Low Power | ||||
and Lossy Networks", Jerry Martocci, Nicolas Riou, | ||||
Pieter Mil, Wouter Vermeylen, | ||||
draft-martocci-roll-building-routing-reqs-01 | ||||
(work in progress), October 2008 | ||||
[I-D.draft-martocci-roll-commercial-routing-reqs] | ||||
"Commercial Routing Requirements in Low Power and | ||||
Lossy Networks", Jerry Martocci, Ted Humpal, Nicolas Riou, | ||||
Jon Williamsson, | ||||
draft-martocci-roll-commercial-routing-reqs-00.txt | ||||
[I-D.draft-vasseur-roll-terminology] | ||||
"Terminology in Low power And Lossy Networks", | "Terminology in Low power And Lossy Networks", | |||
JP Vasseur, draft-ietf-roll-terminology-00 | JP Vasseur, draft-ietf-roll-terminology-00 | |||
(work in progress), October 2008 | (work in progress), October 2008 | |||
Author's Addresses | Author's Addresses | |||
Anders Brandt | Anders Brandt | |||
Zensys, Inc. | Zensys, Inc. | |||
Emdrupvej 26 | Emdrupvej 26 | |||
Copenhagen, DK-2100 | Copenhagen, DK-2100 | |||
End of changes. 3 change blocks. | ||||
29 lines changed or deleted | 3 lines changed or added | |||
This html diff was produced by rfcdiff 1.35. The latest version is available from http://tools.ietf.org/tools/rfcdiff/ |